본문 바로가기 메뉴바로가기

Research Equipment Status

Parallel Processing System for high-speed calculation of large-capacity numerical algorithms

High Performance Computing system capable of large-capacity high-speed computing power
Small LINUX PC cluster for the development of three-dimensional and diverse numerical solutions

Current Status of Coutilization Authorized Research Equipment

Equipment
Equipment Name Introduction Method of Use Status Inquiry
3D Printer

3D 프린터

Model ObJet30 Prime Direct Use Available
Detail
  • - Minimum lamination thickness of 16 microns (0.016 cm) enabling it to display smooth surface and detailed shapes
  • - Plastic materials in various colors, transparent materials, polypropylene(PP) and rubber materials available
  • - Dedicated 3D software(Object Studio) provided by manufacturer
Composition
  • (1) 1 unit (including SW) and 1 host PC
  • (2) 1 Waterjet (Support hydraulic pressure relief device)
  • (3) 1 UPS (uninterruptible power supply)
  • - Net Print Size : 294(X) x 192(Y) x 148(Z)㎜
  • - Lamination thickness : 16 / 28 / 36 ㎛
  • - Input file format : STL
Ultrasonic Equipment

초음파장비

Model ECUBE 12R Direct Use Available
Detail
  • - Visual equipment that provides ultrasound echo image and color Doppler image
  • - Raw data in the form of RF data and IQ data obtainable
  • - Available in research on performance improvement of beamforming algorithm, echo image and color doppler image
Composition
  • (1) Equipment body unit for ultrasonic imaging
  • (2) 2 Probes for ultrasonic scanning : Convex (SC1-4H), Phased array probe (SP1-5)
  • (3) Composed of monitor, storage device etc.
  • (4) Ultrasonic image data can be acquired at a frame rate of 1000 fps or higher
Jupyter HUB

Jupyter HUB

Model SuperServer 1028R-MCtr Direct Use Available Apply on website (jupyter.nims.re.kr)
Usage JupyterHub server interlocked with open problem-solving platform
Composition 17*Node : 2*E5-2600 @2.4GHz, 65GB
EEG Measuring Equipment

뇌파측정 장비

Model SynAmps2 Direct Use / Rental Occupied (KAIST)
Detail As a 64-channel EEG measurement system, it is a device that simultaneously measures the potential measured from contact-type 64-channel electrodes attached to the head, and converts it into a digital signal that is transmitted to the computer
Composition
  • (1) Head cap : Contact-type 64-channel electrode
  • (2) Preamplifiers and Converters : Amplifies and converts the signal into a digital signal
  • (3) SCAN Analysus Version 431 : Connected from the transducer to the computer, it transmits the potential measured from the electrode to the computer.
  • (4) 24bit resolution, 20Khz sampling rate
  • (5) 10G Ohm imput impedance
  • (6) 64 Channel, Low and High pass filter
  • (7) 24nV/bit resolution
Audiovisual Stimulation Equipment

시청각 자극 장비

Model Stim2 Direct Use / Rental Available
Detail A device used in brain wave measurement or behavioral psychology experiment, which elaborately expresses visual and auditory stimuli and measures their responses
Composition
  • (1) PC : A program to create a stimulus sequence is installed
  • (2) Interface : Transmits visual and auditory stimulation points to other devices
  • (3) Earphones : earphones for auditory stimulation
  • (4) Auditory : 24bit resolution, 192kHz sampling rate
  • (5) Visual : 1024x768 monitor resolution, 2ms temporal resolution
Infrared Gas Analysis Equipment

적외선 가스분석 장비

Model EC155 Direct Use / Rental Available
Detail
  • - A device that measures the concentration of carbon dioxide and water vapor at high speed
  • - An analyzer using a closed-path type of infrared absorptivity.
Composition Consists of a sensor and a pump module.
  • - Default measurement speed : 150Hz
  • - Output bandwidth : In accordance with user, 5, 10, 12.5 or 25Hz
  • - operating temperature range : -30℃ ~ +50℃
  • - CO2 measurement performance
  • *Maximum error range according to temperature (At 25℃, 731.6 mg/m3 CO2 gas):
  • -30℃ ~ +15℃ : ±0.3 mg/m3/℃ (±0.164 µmol/mol/℃)
  • 35℃~ 50℃ : ±0.4 mg/m3/℃ (±0.219 µmol/mol℃)
  • - Maximum error range according to temperature in zero CO2 state:
  • -30oC ~ +15oC: ±0.15 mg/m3/oC (±0.0820 µmol/mol/oC)
  • 15oC~ 35°C: ±0.25 mg/m3/°C (±0.137 μmol/mol/°C)
  • 35° ~ 50°C: ±0.3 mg/m3/°C (±0.164 μmol/mol/°C)
  • - Error range according to temperature rise : (Max): ±0.1% of reading/°C
  • - Water vapor sensitivity : (Max): 5.6 x 10-5 mol CO2 /mol H2O
  • - H2O measurement performance
  • * Maximum error range according to temperature (At 25°C, measured with 9 g/m3H2O):
  • 15° ~ 45°C: ±0.01 g/m3/°C (±0.0134 mmol/mol/°C)
  • - Maximum error range according to temperature in zero H2O state :
  • -30° ~ 0°C: ±0.01 g/m3/°C (±0.0134 mmol/mol/°C)
  • 0° ~ 50°C: ±0.005 g/m3/°C (±0.00668 mmol/mol/°C)
  • - Maximum error range according to temperature : (Max): ±0.15% of reading/°C
  • - CO2 Sensitivity : (Max): ±0.05 mol H2O/mol CO2
Closed Loop Eddy Co-dispersion System (Ultrasonic Wind Direction Anemometer)

폐회로 에디공분산시스템 (초음파풍향풍속계)

Model CSAT3 Direct Use / Rental Available
Detail
  • - Uses CSAT3A 3D ultrasonic anemometer to measure eddy covariance
  • - CSAT3 is an ultrasonic anemometer for measuring wind speed in three dimensions. To detect wind, three pairs of non-orthogonally oriented transducers are used, and each pair of transducers transmits and receives ultrasonic signals. By using the speed at which the sound speed signal is transmitted to each transducer, the average horizontal wind speed and direction or turbulence fluctuations of horizontal and vertical winds can be measured, along with the momentum flux of turbulence
Composition 3D ultrasonic wind speed sensor
  • - Model name : CSAT3A
  • - Measuring range : 0 ~ 60 m/s
  • - Initial wind speed : 0.01 m/s
  • - Observation resolution : 0.01m/s(Ux, Uy), 0.005m/s(Uz)
  • - Operating temperature range : -30℃ - 50℃
  • - Output : RS232, 0 ~ 2.5VDC or SDM
Data Log

데이터로그

Model CR5000-RC Direct Use / Rental Available
Detail It is used to record, process, and store the observation data of various sensors at high speed, and is also used to control external devices such as pumps and motors. It is difficult to operate AC power or a computer, and it has the advantage of operating independently even in poor environmental conditions with low power consumption where people are absent.
Composition The CR5000 can measure up to 5000Hz and is equipped with a standard card slot, so you can expand the storage function by adding a CF memory card. Voltage measurement through analog input channel, pulse measurement through pulse counter channel, and external device control through digital input/output port are available.
  • - Operating temperature range : 40℃ ∼ 85℃
  • - Processor : Hiachi SH7034
  • - Memory : SRAM 2MB
  • - Serial interface : RS-232 , CSI/O
  • - Baud rate : 1200 ∼ 115200 bps
Open-Jupyter

Open-Jupyter

Model MacMini Cluster Direct Use Available Apply on website (jupyter.nims.re.kr)
Detail JupyterHub server interlocked with open problem-solving platform
Composition 1*Master : (Mac Pro) X5650 @2.67GHz, 16GB
40*Node : (macmini) i7-3720QM @2.6GHz, 16GB
Large Memory Server for Data Analysis

데이터분석용 대용량메모리 서버

Model HP ProLiant DL580 Gen9 Direct Use Available
Detail As a high-capacity memory server for data analysis, data analysis using in-memory DB is possible. Equipped with GPU computing function, parallel processing of data using GPU is possible. It can be operated by adding an additional GPU.
Composition 2*E7-4850 v3 @2.2Ghz, 960GB
1*NVIDIA Tesla K40C 12GB
Opencomp0

opencomp0

Model Dell PowerEdge R910 Direct Use Available
Detail Public calculation server (internal)
Composition 4*E7-4820 @ 2.0GHz, 256GB
opencomp1

opencomp1

Model Dell PowerEdge R900 Direct Use Available
Detail Public calculation server (internal)
Composition 4*X7350 @ 2.93 GHz, 128GB
opencomp2

opencomp2

Model SuperMicro X8DAH Direct Use Available
Detail Public calculation server (internal)
Composition 2*X5675 @ 3.07GHz, 96GB
Nvidia GTX 680, CUDA 9.2
opencomp3

opencomp3

Model Dell Precision R5500 Direct Use Available
Detail Public calculation server (internal)
Composition 2*X5650 @ 2.67GHz, 48GB
2*Tesla C2075, CUDA 8.0
opencomp4

opencomp4

Model HP ProLiant 580 Gen7 Direct Use Available
Detail Public calculation server (internal)
Composition 4*E7540 @ 2.0GHz, 96GB
opencomp5

opencomp5

Model Dell PowerEdge M1000 w/ M610 Direct Use Available
Detail Public calculation server (internal)
Composition Only 24 of the available 192(HT) cores are occupied due to use of the ScaleMP memory aggregation only license, 192GB
  • 1*Dell PowerEdge R710- 2*X5650 @ 2.67GHz, 24GB
  • 8*Dell Poweredge M610- 2*X5650 @ 2.67GHz, 24GB
opencomp6

opencomp6

Model Dell Precision T7600 Direct Use Available
Detail Public calculation server (internal)
Composition 2*E5-2687W @ 3.1GHz, 256GB
Nvidia GTX 1060. CUDA 10.2

Application for Coutilization Authorized Research Equipment

  • How to Apply
    • After checking the status of the equipment you want to use in cooperation with from the list of coutilization authorized equipment on the website, fill out the application form (Appendix Nos. 2 to 4) and email it to equipment management
    • Equipment manager should verify the application and discuss the availability date and time of allocation with the applicant
  • How to use
    • Direct Use : Receive training from management personnel on how to use, safety rules, etc., and use the equipment within the acceptable range.
    • Analysis test request : Equipment manager conducts the analysis test and notifies the result